implementation section
few fixes in text
Line 1: Line 1:
=MCMTII=
=MCMTII=


[http://www.astrosurf.com/mcmtii/ Link to official webpage] (in French).
[http://www.astrosurf.com/mcmtii/ Link to official webpage] (in French). MCMTII is an open telescope motor control unit. It uses microcontrollers to command stepper motors. It has a hand controller, a serial RS232 interface for setup and control and a SBIG ST-4 compatible interface for autoguiding.


Recent versions (2011) of the MCMTII, which have undergone a few evolutions since MCMTII has been described on the website, only work with the non-free [http://www.prism-astro.com/us/index.php PRISM software] (for windows) in versions 7 or 8 or the Ascom driver.
Recent versions (2011) of the MCMTII, which have undergone a few evolutions since MCMTII has been described on the website, only work with Windows and the non-free [http://www.prism-astro.com/us/index.php PRISM software] in versions 7 or 8, or the Ascom driver. The purpose of this page is to provide resources that will enable the MCMTII to be controlled by free software on other operating systems.


The current source available from the [http://www.astrosurf.com/mcmtii/telechargt.htm download page] is quite old. [[:File:McmtII_dll_v1.2.3.8_source.zip|Here]] is a local copy of this file, version 1.2.3.8. A newer version will be requested soon as well as protocol documentation. It is developed by [http://www.alcor-system.com Alcor System], so does PRISM. The code in Delphi language for Windows.
The source available from the [http://www.astrosurf.com/mcmtii/telechargt.htm download page] is quite old. [[:File:McmtII_dll_v1.2.3.8_source.zip|Here]] is a local copy of this file, version 1.2.3.8. The current version of the DLL, the same than in PRISM v8, has been obtained from the developers (published soon). Protocol documentation is on its way too. It is developed by [http://www.alcor-system.com Alcor System], so does PRISM. The code is in Delphi language for Windows.


==Implementing the library for POSIX systems==
==Implementing the library for POSIX systems==
Line 35: Line 35:
|}
|}


Most commands then fall into the special command category. Data is mostly ascii text, and commands start with an identifier, which is the ascii value of a letter. We will now see the list of special commands, separated in two: the list of setup commands, and the list of runtime command.
Most commands then fall into the ''special command'' category. Commands start with an identifier, the ascii value of a letter. We will now see the list of special commands, separated in two categories: the list of runtime commands and the list of setup commands.


Bytes from the response buffer are referenced as {i} where i is the i<sup>th</sup> byte. PEC is periodic error correction. [http://canburytech.net/DriftAlign/DriftAlign_3.html KING] is a method for refraction compensation by offsetting the telescope pointing.
Bytes from the response buffer are referenced as {i} where i is the i<sup>th</sup> byte. PEC is periodic error correction. [http://canburytech.net/DriftAlign/DriftAlign_3.html KING] is a method for refraction compensation by offsetting the telescope pointing.
Line 149: Line 149:
|-
|-
|saving setup (write to EEPROM)
|saving setup (write to EEPROM)
|'L', setup command ID, data ...
|'L', ''setup command ID'', data ...
|none
|none
|-
|-
Line 170: Line 170:
|}
|}


For setup command IDs, see procedure <code>TSetupTelescope.Button_EcrireClick</code> in Setup.pas. Speeds, precisions and corrections are set using these commands.
For ''setup command IDs'', see code of procedure <code>TSetupTelescope.Button_EcrireClick</code> in Setup.pas. Speeds, precisions and corrections are set using these commands.

Revision as of 21:14, 30 August 2012

MCMTII

Link to official webpage (in French). MCMTII is an open telescope motor control unit. It uses microcontrollers to command stepper motors. It has a hand controller, a serial RS232 interface for setup and control and a SBIG ST-4 compatible interface for autoguiding.

Recent versions (2011) of the MCMTII, which have undergone a few evolutions since MCMTII has been described on the website, only work with Windows and the non-free PRISM software in versions 7 or 8, or the Ascom driver. The purpose of this page is to provide resources that will enable the MCMTII to be controlled by free software on other operating systems.

The source available from the download page is quite old. Here is a local copy of this file, version 1.2.3.8. The current version of the DLL, the same than in PRISM v8, has been obtained from the developers (published soon). Protocol documentation is on its way too. It is developed by Alcor System, so does PRISM. The code is in Delphi language for Windows.

Implementing the library for POSIX systems

The obvious choice would be to code a portable (POSIX) C library. However, it must be considered that the right choice is not the obvious choice, but the most useful choice. Is it better to write a library or an API? If it's an API, in what programming language? Software that will be using the library must be studied before starting to write crazy things.

RS232 protocol

The protocol for the serial link is quite simple, based on request-response exchanges. Is it the LX200 protocol? How does it differ from it?

Three types of messages exist, as explained in the following table. axis_id is `E0' for alpha axis (right ascension), `E1' for delta axis (declination). In the fields request and response of the table, values or identifiers represent bytes, and they are separated by commas. Comments are between parentheses.

Command Request Response
device ready axis_id, FF 01 (success value)
read encoder axis_id, F1 + byte number [0..3] the requested byte from the int32 value
special command axis_id, {7 bytes maximum for the command} 06, {data} (if response data is available)

Most commands then fall into the special command category. Commands start with an identifier, the ascii value of a letter. We will now see the list of special commands, separated in two categories: the list of runtime commands and the list of setup commands.

Bytes from the response buffer are referenced as {i} where i is the ith byte. PEC is periodic error correction. KING is a method for refraction compensation by offsetting the telescope pointing.

Special commands for telescope operation mode

Command Request Response
from RetrieveData
AlphaDelta_Internal, get step values for PEC
'r', 0, 0, 0, 0 10 bytes, containing as follows:
current speed steps per second = 625000 / {3} / 10 + {2} + 256 * {1}
index PecC = {4}
Pec step = 256*{5} + {6}
another step value? 256*{7}+2*{8}
Panel info pec = {9} & 0F
Pec state 1 = {9}
Pec state 2 = {10}, boolean value indicating if parked
from RetrieveData
AlphaDelta_Internal, update current speed (or stop moving)
'R', {3 bytes (same format than 3 first bytes of 'r' reply)} none
from RetrieveData
AlphaDelta_Internal, activate PEC
'L', 2F, activate?1:0, 0, 0 none
from RetrieveData
AlphaDelta_Internal, erase PEC
'e', 0, 0, 0, 0 none
from RetrieveData
AlphaDelta_Internal, save PEC
'E', 0, 0, 0, 0 none
from TelescopeMoveAxe, move number of steps 'p', {4 bytes of int32 number of steps} none
from MoveTelescope, north or west move max speed 'X', 0, 0, 0, 0 none
from MoveTelescope, north or west move medium speed 'G', 0, 0, 0, 0 none
from MoveTelescope, north or west move min speed 'D', 0, 0, 0, 0 none
from MoveTelescope, south or east move max speed 'W', 0, 0, 0, 0 none
from MoveTelescope, south or east move medium speed 'F', 0, 0, 0, 0 none
from MoveTelescope, south or east move min speed 'Q', 0, 0, 0, 0 none
from Stop_Telescope, stop moving, resume sideral speed 'S', 0, 0, 0, 0 none
from STOP_ALL_Telescope, move to parking position 'P', 0, 0, 0, 0 none
from ReturnToSideralSpeed, no park mode 'N', 0, 0, 0, 0 none

Special commands for telescope setup mode

Command Request Response
loading setup (read from
MCMTII's EEPROM)
'K', 0, 0, 0, 0 48 bytes, containing as follows:
{1..3} is guiding speed
{4..5} is correction P speed
{6..7} is correction M speed
{8..9} is point L
{10..11} is point R
{12} is acceleration
{13} is boolean for inversion
{29..30} is the resolution
saving setup (write to EEPROM) 'L', setup command ID, data ... none
get MCMTII's version 'V', 0, 0, 0, 0 a string up to 80 characters
flash EEPROM (put device in special programming mode) 'M', 0, 0, 0, 0, followed by data: none
dev_id (initialize transfer) EB (IDACK)
E3 (WRITEBOOT), address high, address low, length (10), checksum, {10 bytes data} E7 (DATA_OK), E4 (WOK) (success)
ED (DONE), {whatever?} E4 (WOK) (success)

For setup command IDs, see code of procedure TSetupTelescope.Button_EcrireClick in Setup.pas. Speeds, precisions and corrections are set using these commands.