Command Request Response
get current guiding speed and data for internal PEC, from RetrieveData
AlphaDelta_Internal
'r', 0, 0, 0, 0 10 bytes, containing as follows (decimal values):
current guiding speed steps per second = 625000 / {3} / 10 + {2} + 256 * {1}
index PecC (PEC_BASE) = {4}
Pec step = 256*{5} + {6}
another step value? 256*{7}+2*{8}
Pec state 1 = {9} (0: no PEC, 1: PEC activated, 2: PEC recording about to start, 3: PEC recording)
Park state = {10} (0 or 1)
activate PEC, from RetrieveData
AlphaDelta_Internal
'L', 2F, activate?1:0, 0, 0 (see setup commands below) none
erase PEC, from RetrieveData
AlphaDelta_Internal
'e', 0, 0, 0, 0 none
save PEC (start recording), from RetrieveData
AlphaDelta_Internal
'E', 0, 0, 0, 0 none