(Creating split page for Siril tutorial)
 
No edit summary
(19 intermediate revisions by 2 users not shown)
Line 1: Line 1:
=Siril processing tutorial=
<languages />
<translate>


=Siril processing tutorial= <!--T:1-->
<!--T:2-->
* [[Siril:Tutorial_import|Convert your images in the FITS format Siril uses (image import)]]
* [[Siril:Tutorial_import|Convert your images in the FITS format Siril uses (image import)]]
* [[Siril:Tutorial_sequence|Work on a sequence of converted images]]
* [[Siril:Tutorial_sequence|Work on a sequence of converted images]]
* [[Siril:Tutorial_preprocessing|Pre-processing images]]
* [[Siril:Tutorial_preprocessing|Pre-processing images]]
* &rarr; '''Registration (manual image alignment)'''
* &rarr; '''Registration (Global star alignment)'''
* [[Siril:Tutorial_stacking|Stacking]]
* [[Siril:Tutorial_stacking|Stacking]]


==Registration (manual image alignment)==
==Registration (Global star alignment)== <!--T:3-->


Siril has an automatic registration capability, but I can't say it's working fine at all. I suggest you use it as a first step if the quality of your images is good, or not at all if stars are not round, if focus is bad or if there is a lot of noise. Currently, only translation is used for image alignment, no rotation.
<!--T:4-->
Siril has four automatic registration tools. In this example we will use the all automatic one: Global star alignment. This method is dedicated to the deep-sky registration, and contrary to the One Star registration, it handles the rotation of images between each others.


The first step is to load the sequence, if we continue this tutorial this will be the pp_m27 sequence. Go back to the sequence tab, and click on "search sequence" to find the new sequence created by the pre-processing. Select the pp_ sequence, which will open the image preview windows if not already opened, and display the first image of the sequence.
<!--T:5-->
After debayering (in previous step), the new sequence is loaded and you can check it in the "image sequences" tab. From this tab, you can change the image being viewed in the grey and colour windows, include or exclude them from a user-defined selection that will later be used to indicate which files should be stacked or not, and set the reference image. While browsing through the images of the sequence, a reference image may be set to a specific image if you think it has a better quality than the others, or if it's best centred. Note that when the reference image is set, it will be saved in the sequence and it will be opened first when loading the sequence the following time.


[[File:Siril load pp sequence.png]]
<!--T:7-->
 
An alternative to the use of buttons of the sequence tab is to use the ''sequence list''. Click on the dedicated button [[File:Siril_button_seq.png|24px|frameless|link=|middle]].
[[File:Siril pp seq loaded.png]]
 
From this tab, you can change the image being viewed in the grey and colour windows, include or exclude them from a user-defined selection that will later be used to indicate which files should be stacked or not, and set the reference image. While browsing through the images of the sequence, a reference image may be set to a specific image if you think it has a better quality than the others, or if it's best centred. Note that when the reference image is set, it will be saved in the sequence and it will be opened first when loading the sequence the following time.
 
An alternative to the use of buttons of the sequence tab is to use the ''sequence list''. Double click on the grey window to make it appear:


<!--T:8-->
[[File:Siril sequence list.png|700px]]
[[File:Siril sequence list.png|700px]]


You can then open an image of the sequence by double-clicking on its line, and select (include or exclude) the image from the sequence by checking or unchecking its box. X Y and FWHM columns will be displayed later, when registration data is available. In the image above, you can see that two images have already been excluded from the sequence.
<!--T:9-->
To make registration, just click on "Go Register" button. Everything will be automatic. The algorithm tries to match triangle patterns in order to align images and you can check each step of registration in the console output.


To do the automatic registration, select a star in a grey image, preferably in the same layer than the layer used for registration (green by default) to be sure that the star appears in this layer, and click the "Go register" button.
<!--T:16-->
[[File:Siril_global_star_reg.png|700px]]


[[File:Siril auto registration screen.png]]
<!--T:17-->
A new sequence will be created and automatically loaded at the end of the process. In addition, an average of FWHM is computed and provided in this sequence. It is thus possible to select best images for stacking.


[[File:Siril registration done area selected.png|700px]]
===Special cases with low sigma/noise ratio=== <!--T:18-->
In some cases, due to high noise level, automatic registration gives wrong results by confusing noise and stars during star detection. To overcome this issue, Siril provides parameters adjustable parameters offering a better tool detection. These parameters are located in the Dynamic PSF window.
[[File:Siril_PSF_param.png|700px]]


You can view the registration data in the list on the left when you are viewing the layer corresponding to the registration layer. You can also see in the image above that the reference image is on the yellow line and the currently displayed image has its name in bold.
<!--T:19-->
In our case, increasing thershold value will give better results.


----


Now, in order to validate the registration, which is never perfect, there is a way to display the reference image over the other images, taking into account the translation data, and also adjust this data to have a better fit. This is done in the preview area of the main window, in the registration tab.
<!--T:15-->
 
Next item of the tutorial: [[Siril:Tutorial_stacking|Stacking]].
Click on "Set first preview", then click on a star in the image when you have loaded the registration layer of the reference image. The preview area of the image in native resolution will be displayed in the main window. Do the same for the second preview, on the opposite of the image if several stars are available.
 
[[File:Siril manual registration regions.png|700px]]
 
[[File:Siril_registration_previews.png]]
 
Now when you select an image in the sequence, you will see this image's layer's preview appearing with optionally the reference image's preview in transparency. Verify that both stars are aligned, and if not, use the X translation and Y translation spins to change it (use the mouse wheel or the arrows, it's easier). When the automatic registration doesn't work well, you have that kind of result at first:
 
[[File:Siril regpreview not aligned.png]]


If you can only have one star well aligned like the first one below and the other star way too far from the reference star like the second one below, it means that the camera has turned between the shots, and currently Siril is not able to rotate the frames, so you can exclude it from the sequence.
</translate>
 
[[File:Siril regpreview aligned1.png]]
 
You should be able to get that kind of result if camera was not rotated:
 
[[File:Siril regpreview aligned2.png]]
 
One you have done it with all images, you will have the final list of selected images from the sequence, and much better alignment data than with the automatic registration:
 
[[File:Siril_registration_done.png|700px]]
 
 
Next item of the tutorial: [[Siril:Tutorial_stacking|Stacking]].

Revision as of 20:32, 5 September 2016

Other languages:

Siril processing tutorial

Registration (Global star alignment)

Siril has four automatic registration tools. In this example we will use the all automatic one: Global star alignment. This method is dedicated to the deep-sky registration, and contrary to the One Star registration, it handles the rotation of images between each others.

After debayering (in previous step), the new sequence is loaded and you can check it in the "image sequences" tab. From this tab, you can change the image being viewed in the grey and colour windows, include or exclude them from a user-defined selection that will later be used to indicate which files should be stacked or not, and set the reference image. While browsing through the images of the sequence, a reference image may be set to a specific image if you think it has a better quality than the others, or if it's best centred. Note that when the reference image is set, it will be saved in the sequence and it will be opened first when loading the sequence the following time.

An alternative to the use of buttons of the sequence tab is to use the sequence list. Click on the dedicated button .

To make registration, just click on "Go Register" button. Everything will be automatic. The algorithm tries to match triangle patterns in order to align images and you can check each step of registration in the console output.

A new sequence will be created and automatically loaded at the end of the process. In addition, an average of FWHM is computed and provided in this sequence. It is thus possible to select best images for stacking.

Special cases with low sigma/noise ratio

In some cases, due to high noise level, automatic registration gives wrong results by confusing noise and stars during star detection. To overcome this issue, Siril provides parameters adjustable parameters offering a better tool detection. These parameters are located in the Dynamic PSF window.

In our case, increasing thershold value will give better results.


Next item of the tutorial: Stacking.